Laparoscopic Diastasis Correction
Laparoscopic cosmetic correction of diastasis recti and umbilical hernia (punctures in the bikini area)
Автор: Puchkov K. V.
Laparoscopic cosmetic correction of diastasis recti and umbilical hernia (punctures in the bikini area)
Surgeon: professor K.V. Puchkov (2019).
The patient is 22 years old. Two childbirth in history. It has high aesthetic requirements for surgery. Diastasis recti 17x4.5 cm. Reversible umbilical hernia 3 cm. The film shows the technique of cosmetic correction of diastasis recti and umbilical hernia by suturing them with the V-lock system (MEDTRONIC COVIDIEN) on an atraumatic 2-0 non-absorbable needle. This stage is performed through trocars inserted in the bikini area. The final stage is the closure of the suture line with a Parietex Composite composite mesh (20x16 cm) and its fixation with transperitoneal sutures and a combination of absorbable and nonabsorbable AbsorboTack tacker bags using the ProTack MEDTRONIC COVIDIEN hernia stapler. The duration of the operation is 40 minutes.
You can read more about the techniques on the personal site of Professor Konstantin Viktorovich Puchkov.
Laparoscopic correction of diastasis recti through the scar after Caesarean section
Автор: Puchkov K. V.
Laparoscopic correction of diastasis recti through the scar after Caesarean section
Surgeon: professor K.V. Puchkov (2019).
The patient suffered a Caesarean section 2 years ago. Diastasis recti 16x4 cm. The film shows the technique of cosmetic correction of diastasis of the rectus abdominis muscles by suturing them with the V-lock system (MEDTRONIC COVIDIEN) on an atraumatic needle with a non-absorbable 2-0 thread. This stage is performed through trocars inserted in the scar zone after the Caesarean section. The final stage is the closure of the suture line with a Parietex Composite mesh (20x16 cm) and its fixation with transperitoneal sutures and a combination of absorbable and nonabsorbable AbsorboTack tacker bags using the ProTack MEDTRONIC COVIDIEN hernia stapler. The duration of the operation is 50 minutes.
You can read more about the techniques on the personal site of Professor Konstantin Viktorovich Puchkov.
Laparoscopic correction of diastasis recti and umbilical hernia, cholecystectomy
Автор: Puchkov K. V.
Laparoscopic correction of diastasis recti and umbilical hernia, cholecystectomy
Surgeon: professor K.V. Puchkov (2018).
Overweight patient. Gallbladder size 22 cm x 6 cm. Massive adhesions. The calculus size about 5.5 cm. Diastasis 18x5 cm, the size of the hernia gate is 4 cm. During the first stage, cholecystectomy is performed. Further, in the video it shows the technique of correction of diastasis recti and umbilical hernia by suturing them with the V-lock non-absorbable 2-0 thread (MEDTRONIC COVIDIEN) on an atraumatic needle. This stage is performed through trocars inserted for cholecystectomy. The final stage is the closure of the suture line with a ParietexComposite mesh (20x16 cm) and its fixation with transperitoneal sutures and a ProTack (MEDTRONIC COVIDIEN) hernia stapler. The duration of the whole simultaneous operation is 1 hour 30 minutes, the stage of correction of diastasis is 40 minutes.
You can read about this technique in detail on the personal cite of Professor Puchkov Konstantin Viktorovich. To go to the link.